Property | Test Method | XP14
| XFP14
| XP38
| XFP38
|
R-Value
(°F-ft²-h/Btu)1 | ASTM C 518
(@75°F Mean Temperature) | 1.0
| 3.0
| 1.5
| 3.6
|
Water Vapor Permeance
(perm)
| ASTM E 96
Procedure A
| 1.7
| 1.7
| 1.3
| 1.3
|
Water Absorption
(max,% by Volume)
| ASTM C 272
| 2.0
| 2.0
| 2.0
| 2.0
|
Compressive Strength
(psi @ 10% deflection)
| ASTM D 1621
| 12
| 12
| 14
| 14
|
Fire Characteristics2
Flame Spread
Smoke Development
| ASTM
E 84/UL 723
|
25
250
|
25
250 |
10
45-140
|
10
45-140
|
|
| XP14
| XFP14
| XP38
| XFP38
|
Length3
| 50'
| 50'
| 50'
| 50'
|
Width3
| 4'
| 4' | 4' | 4' |
Nominal Thickness
| 1/4"
| 1/4"
| 3/8"
| 3/8"
|
Square Feet/Pallet
| 9,000
| 9,000
| 6,000
| 6,000
|
1 Specimens were aged and tested in accordance with FTC Rule (16 CFR, Part 460). The R-values shown for GreenGuard®-FP1450, GreenGuard®-XFP14, GreenGuard®-FP38, and GreenGuard®-XFP38 are system R-values calculated in accordance with the “ASHRAE Handbook of Fundamentals” using a ½” uniform, parallel dead air space. The R-values of these products installed without the benefit of a dead air space are 1.0 (GreenGuard®-FP1450 and GreenGuard®-XFP14) and 1.5 (GreenGuard®-XFP38).
2 These numerical flame spread and smoke ratings are not intended to reflect hazards presented by these materials under actual fire conditions (core data).
3 These dimensions apply to each fanfold bundle.