SLX Sheathing
SLX Sheathing is an extruded polystyrene (XPS) board that gives you an edge on moisture resistance and thermal performance. With an R-Value of 5.0 per inch of thickness, it is an ideal thermal insulator that increases a home’s energy efficiency. And because it’s made of XPS, the board doesn’t absorb water, allowing it to retain its insulating properties over time. SLX has interlocking shiplap edges that reduce energy-robbing seams and gaps, while also providing an extra barrier against moisture infiltration. Tough film facers on both sides of the board produce greater durability and less waste.
|
Property | Test Method | 1/2"
| 3/4" | 1"
|
Thermal Resistance, R-Value
(ºF-ft²-h/Btu)1
| ASTM C 518
(@ 75ºF Mean Temperature)
| 3.0
| 3.8
| 5.0
|
Water Absorption
(Max.% by Volume)
| ASTM C 272
| 0.1
| 0.1
| 0.1
|
Fire Characteristics2
Flame Spread
Smoke Development
| ASTM E 84/UL 723
| 1.0
60-200
| 1.0
60-200
| 1.0
60-200
|
Max. Recommended Use Temp.
(°F )
|
| 165
| 165
| 165
|
|
Board Dimensions
| 4' x 8' | 4' x 8'
| 4' x 8'
| 4' x 9'
| 4' x 9'
|
| Thickness |
1/2"
Nominal
Thickness
| 3/4"
| 1"
| 1/2"
| 3/4"
|
Sheets/Bundle
| 20
| 14
| 16
| 20
| 14
|
Sheets/Pallet
| 160
| 126
| 96
| 160
| 126
|
Square Feet/Pallet
| 5,120
| 4,032
| 3,072
| 5,760
| 4,536
|
1 Specimens were aged and tested in accordance with FTC Rule (16 CFR, Part 460) and ASTM C578 (1" only).
2 These numerical flame spread and smoke ratings are not intended to reflect hazards presented by this material under actual fire conditions. See UL Classification Certificate A183.
Disclaimer