| Property | Test Method | RainDrop@ 3D |
Thickness1
(inches)
(mils) | ASTM D 1777 |
.020
20 |
Weight
(lbs./1,000 ft.²) | ASTM D 3776 | 21 |
Tensile Strength
(lbs./in.,MD/TD)2 | ASTM D 882 | 56/30 |
Trapezoid Tearing Strength
(lbs., MD/TD)2 | ASTM D 4533 | 25/41 |
Burst Strength
(psi) | ASTM D 751 | 155 |
Water Resistance
(minutes) | ASTM D 779 | >120 |
| Water Penetration Resistance (CM H2O) | AATCC-127 | >500 |
Drainage Efficiency3
(% Water Drained) | ASTM E 2273 | >90 |
Water Vapor Permeance
(perms) | ASTM E 96
Desiccant Method | 16 |
Water Vapor Transmission Rate
(g/m²/24 hrs.) | ASTM E 96
Desiccant Method | 128 |
Air Permeance (L/s/m2 @ 75 Pa)
(cfm/ft2 @ 1.57 psf) | ASTM E 2178 | 0.001
0.000 |
Air Resistance/Wall Assembly
(L/s/m2 @ 75 Pa)
(cfm/ft2 @ 1.57 psf) | ASTM E 2357
| <001
0.00 |
Air Penetration Resistance
(seconds per 100 cc)
| TAPPI T-460
| >800
|
Air Leakage Rate/Air Resistance
(cfm/ft²@1.57 psf/25 mph) | ASTM E 283 | 0.01 |
Structural Integrity
(minimum 1 hr. @ 500 Pa/65 mph) | ASTM E 330
Procedure A | Pass |
Water Resistance
(15 min.@ 27 Pa/15 mph) | ASTM E 331 | Pass |
Fire Characteristics4
Flame Spread
Smoke Developed
| ASTM E 84
| Class A
0
15 |
|
| Roll Size | 3' x 125' | 9' x 125' | 10' x 125' |
| Square Feet/Roll | 375 | 1,125 | 1,250 |
| Rolls/Pallet | 84 | 40 | 40 |
| Pallet Size | 48" x 96" | 42" x 109" | 42" x 120" |
1 Low Point (.010 inches/10 mils), High Point (.020 inches/20 mils).
2 Machine Direction/Cross Direction.
3 Drainage testing was conducted in accordance with ASTM E 2273-03 using a cementitious base coat as required for EIFS and adhered veneers. The GreenGuard
® RainDrop
® was installed directly over the sheathing and the exterior side of the RainDrop
® was covered with a layer of Grade D water-resistive barrier/building paper as required in the International Residential Code for stucco wall assemblies.
4 These numerical flame spread and smoke ratings are not intended to reflect hazards presented by this material under actual fire conditions.